We are always sure to listen to our customers needs and provide the requested services for the best price on the entire internet plus guarantee them 99.9% uptime and support. We believe that all of our customers should always be happy with their services with us therefore we constantly take great time and care in carrying out daily maintenance which ensures that we do not cause any upsets.
All packages are hosted on UK Servers with very high specs.

Server Status
Shoutcast: Online
Windows: Online
Flash: Online

LiveZilla Live Help

• Network
Data Center is connected to the Internet with highly redundant network through multiple Gigabit backbones having multiple peering with other networks.

Hardware Guarantee
Servers deployed at the Data Center includes hardware replacement guarantee. In case of any hardware failure, the hardware is immediately replaced.

• Security
Data center located inside its own secure compound, with 2.4 and 3 meter fencing and electric gate entry Equipped & monitored round the clock with closed circuits. Strict access controls are implemented including surveillance cameras, finger-print as well as Keycard system in order to manage entries.

• Electrical Capacity
Equal Power distribution (60 watts per sq. ft.- 80 watts per sq. ft). Each cabinet 4' x 6' gets 110 volt, 20 amp circuit. The main power sums up to 480 volt, 3 phase. power supplies are now also activated in Multiple DC.

Power
In the unlikely event of a power outage from local power grid, all data centers' power systems are designed to run uninterrupted with the help of Two 2000KW auto-switched power generators and centralized UPS systems. Generators are regularly tested & can be used in emergency event of extended utility power outages.

• Precision Environment
Computerized Fully master-planned rise system / HVAC pipe system / Electrically monitoration. HVAC (Heating Ventilation Air Conditioning) systems are N+1 redundant, ensuring that a duplicate system can immediately come online in the event of an HVAC system failure.

• Fire Protection System
Wet Risers set in at every square position.FM-200 system is installed. The advanced fire protection system prevents fires from spreading in the unlikely event one should occur.

• Technical Specifications
Own 5mW on-site sub-station
2.5mW backup on-site sub-station
Perkins generator connected via ATS systems
2 seperate fibre duct points into the building
N+1 PowerWave UPS system
N+1 Airedale Air Handling system
~20c +/- 2c data floor temperature
16 Amp feed per equipment rack
24x7 secure entry via PAC-TAG system, with 4 layer entry
24x7 qualified engineers available for remote hands service
450mm heavy duty raised data flooring